摘要(Abstract):
[目的]克氏针张力带联合铆钉喙锁韧带重建治疗NeerⅡ锁骨远端骨折的临床与影像学评估。[方法]自2008~2012年,本院共有17例NeerⅡ锁骨远端骨折患者行克氏针张力带联合铆钉喙锁韧带重建治疗,通过Constant、DASH评分、骨折愈合时间及喙锁间距对其临床及影像学结果进行评估。[结果]平均随访24.2个月(12~49个月),其中16例患者骨折获得愈合,愈合时间平均3.8个月,1例在术后1周克氏针松脱,后行锁骨远端切除术。15例患者在末次随访时维持解剖复位,但有1例患者患侧喙锁间距较健侧增加40.3%,1例患者锁骨上不可吸收缝线周围的骨道在末次17个月随访时仍较明显并有所增大,1例患者出现迟发性感染但得到了良好的控制,但这些患者患肩均恢复到了术前的活动水平,且在随访过程中没有出现影响患者日常活动的症状。末次随访时Constant和DASH评分分别为97.7分(72~100分)和1.9分(0~26.5分)。[结论]克氏针张力带联合铆钉喙锁韧带重建是NeerⅡ锁骨远端骨折治疗的一种良好的初始选择,其不仅可以获得良好的关节功能,而且并发症较少。
关键词(KeyWords): 锁骨远端骨折;NeerⅡ;克氏针张力带;铆钉;喙锁韧带
基金项目(Foundation):
作者(Author): 江涛;苏海涛;朱兴阳;刘子桃;黄永明;徐伟龙;肖大为;黄国钦;
Email:
DOI:
参考文献(References):
- [1]Madsen W,Yaseen Z,LaFrance R,et al.Addition of a suture anchor for coracoclavicular fixation to a superior locking plate improves stability of typeⅡB distal clavicle fractures[J].Arthroscopy,2013,29:998-1004.
- [2]Martetschlger F,Kraus TM,Schiele CS,et al.Treatment for unstable distal clavicle fractures(Neer 2)with locking T-plate and additional PDS cerclage[J].Knee Surg Sports Traumatol Arthrosc,2013,5:1189-1194.
- [3]Rijal L,Sagar G,Joshi A,et al.Modified tension band for displaced type 2 lateral end clavicle fractures[J].Int Orthop,2012,7:1417-1422.
- [4]Hsu TL,Hsu SK,Chen HM,et al.Comparison of hook plate and tension band wire in the treatment of distal clavicle fractures[J].Orthopedics,2010,12:879-883.
- [5]Yoo JH,Chang JD,Seo YJ,et al.Stable fixation of distal clavicle fracture with comminuted superior cortex using oblique T-plate and cerclage wiring[J].Injury,2009,4:455-457.
- [6]Kalamaras M,Cutbush K,Robinson M.A method for internal fixation of unstable distal clavicle fractures:early observations using a new technique[J].J Shoulder Elbow Surg,2008,1:60-62.
- [7]Flinkkila T,Ristiniemi J,Lakovaara M,et al.Hook-plate fixation of unstable lateral clavicle fractures:a report on 63 patients[J].Acta Orthop,2006,4:644-649.
- [8]Robinson CM,Akhtar MA,Jenkins PJ,et al.Open reduction and endobutton fixation of displaced fractures of the lateral end of the clavicle in younger patients[J].J Bone Joint Surg Br,2010,6:811-816.
- [9]Lee YS,Lau MJ,Tseng YC,et al.Comparison of the efficacy of hook plate versus tension band wire in the treatment of unstable fractures of the distal clavicle[J].Int Orthop,2009,5:1401-1405.
- [10]Shin SJ,Roh KJ,Kim JO,et al.Treatment of unstable distal clavicle fractures using two suture anchors and suture tension bands[J].Injury,2009,40:1308-1312.
- [11]Largo RD,Rudin MA,Hotz TK,et al.Anatomic reconstruction of unstable lateral clavicular fractures[J].J Trauma,2011,5:1348-1351.
- [12]Gerhardt DC,Van Der Werf JD,Rylander LS,et al.Postoperative coracoid fracture after transcoracoid acromioclavicular joint reconstruction[J].J Shoulder Elbow Surg,2011,5:6-10.
- [13]Oh JH,Kim SH,Lee JH,et al.Treatment of distal clavicle fracture:a systematic review of treatment modalities in 425 fractures[J].Arch Orthop Trauma Surg,2011,4:525-533.
- [14]Lee KW,Lee SK,Kim KJ,et al.Arthroscopic-assisted locking compression plate clavicular hook fixation for unstable fractures of the lateral end of the clavicle:a prospective study[J].Int Orthop,2010,6:839-845.
- [15]Stegeman SA,Nacak H,Huvenaars KH,et al.Surgical treatment of Neer type-Ⅱfractures of the distal clavicle.A meta-analysis[J].Acta Orthop,2013,2:184-190.