摘要(Abstract):
全髋关节置换术是治疗多种髋关节疾病的一种有效方式,多项研究发现术后假体的稳定性及多种并发症的发生均与关节周围生物力学因素有关,但髋关节复杂的解剖结构使得在体内和实验室对其进行生物力学研究非常困难。有限元分析对复杂物体的生物力学性能分析具有独特的优势,现已被成功应用于人体骨骼、关节和肌肉的相关研究,在骨科生物力学领域占有重要的地位。本文对近几年来有限元分析应用于全髋关节置换中的相关研究进行了较详细的总结,归纳了目前最新的研究进展及存在的问题,为以后的研究指明了方向。
关键词(KeyWords): 有限元分析;全髋关节置换;生物力学;假体设计
基金项目(Foundation):
作者(Author): 斯海波;曾羿;兰平文;沈彬;裴福兴;
Email:
DOI:
参考文献(References):
- [1]Ramos A,Duarte RJ,Relvas C,et al.The influence of acetabular bone cracks in the press-fit hip replacement:Numerical and experimental analysis[J].Clin Biom(Bristol,Avon),2013,6:635-641.
- [2]Ghaffari M,Nickmanesh R,Tamannaee N,et al.The impingementdislocation risk of total hip replacement:effects of cup orientation and patient maneuvers[R].34thAnnual International Conference of the IEEE Engineering in Medicine and Biology Society.IEEE Engineering in Medicine and Biology Society,2012:6801-6804.
- [3]Sakai R,Takahashi A,Takahira N,et al.Hammering force during cementless total hip arthroplasty and risk of microfracture[J].Hip Inter,2011,3:330-335.
- [4]Brekelmans WA,Poort HW,Slooff TJ.A new method to analyse the mechanical behaviour of skeletal parts[J].Acta Orthop Scand,1972,5:301-317.
- [5]聂涌,石小军,裴福兴.步态分析应用于全髋关节置换的研究进展[J].中国矫形外科杂志,2013,11:1106-1110.
- [6]Norman TL,Shultz T,Noble G,et al.Bone creep and short and long term subsidence after cemented stem total hip arthroplasty(THA)[J].J Biomech,2013,5:949-955.
- [7]钟世镇,尹庆水,章莹.临床数字骨科学-创新理论体系与临床应用[M].北京:人民军医出版社,2011:51-56.
- [8]Tarala M,Janssen D,Telka A,et al.Experimental versus computational analysis of micromotions at the implant-bone interface[J].J Eng Med,2011,1:8-15.
- [9]Tarala M,Janssen D,Verdonschot N.Toward a method to simulate the process of bone ingrowth in cementless THA using finite element method[J].Med Eng Physics,2013,4:543-548.
- [10]Kallivokas LF,Na SW,Ghattas O,et al.Assessment of a fictitious domain method for patient-specific biomechanical modelling of press-fit orthopaedic implantation[J].Computer Methods Biomech Biomed Eng,2012,5:501-516.
- [11]Lerch M,Windhagen H,Stukenborg-Colsman CM,et al.Numeric simulation of bone remodelling patterns after implantation of a cementless straight stem[J].Inter Orthop,2013,12:2351-2356.
- [12]Dubov A,Kim SY,Shah S,et al.The biomechanics of plate repair of periprosthetic femur fractures near the tip of a total hip implant:the effect of cable-screw position[J].J Eng Med,2011,9:857-865.
- [13]Elkins JM,O'Brien MK,Stroud NJ,et al.Hard-on-hard total hip impingement causes extreme contact stress concentrations[J].Clin Orthop,2011,2:454-463.
- [14]Bonnin MP,Archbold PH,Basiglini L,et al.Should the acetabular cup be medialised in total hip arthroplasty[J].Hip Inter,2011,4:428-435.
- [15]Kunze M,Schaller A,Steinke H,et al.Combined multi-body and finite element investigation of the effect of the seat height on acetabular implant stability during the activity of getting up[J].Computer Methods Programs Biomed,2012,2:175-182.
- [16]Zhao X,Chosa E,Yamako G,et al.Effect of acetabular reinforcement ring with hook for acetabular dysplasia clarified by three-dimensional finite element analysis[J].J Arthroplasty,2013,10:1765-1769.
- [17]严世贵,吴浩波,陈维善,等.全髋关节置换后聚乙烯内衬应力的弹塑性有限元分析[J].中华骨科杂志,2004,4:211-215.
- [18]Hirata Y,Inaba Y,Kobayashi N,et al.Comparison of mechanical stress and change in bone mineral density between two types of femoral implant using finite element analysis[J].J Arthroplasty,2013,10:1731-1735.
- [19]Liu WG,Liu SH,Yin QF,et al.Biomechanical characteristics of hip prosthesis in hip arthroplasty treating elderly patients with Evans I-III intertrochanteric fracture of femur[J].Acta Academiae Medicinae Sinicae,2013,1:108-111.
- [20]Chen DW,Lin CL,Hu CC,et al.Biomechanical consideration of total hip arthroplasty following failed fixation of femoral intertrochanteric fractures a finite element analysis[J].Med Eng Physics,2013,5:569-575.
- [21]林凤飞,郑明,林朝晖,等.人工髋关节不同材料假体对骨界面的应力分布研究[J].中国矫形外科杂志,2008,7:540-550.
- [22]Tavakkoli Avval P,Klika V,Bougherara H.3D bone evolution after total hip arthroplasty:computational study using irreversible thermodynamics[J].J Biomech Eng,2014,5:051002.
- [23]Elkins JM,Pedersen DR,Callaghan JJ,et al.Bone on bone versus hardware impingement in total hips:a biomechanical study[J].Iowa Orthop J,2012,32:17-21.
- [24]Shen FW,Lu Z,Mc Kellop HA.Wear versus thickness and other features of 5 Mrad crosslinked UHMWPE acetabular liners[J].Clin Orthop,2011,2:395-404.
- [25]Gargiulo P,Petursson T,Magnusson B,et al.Assessment of total hip arthroplasty by means of computed tomography 3D models and fracture risk evaluation[J].Artificial Organs,2013,6:567-573.
- [26]Sakai R,Kikuchi A,Morita T,et al.Hammering sound frequency analysis and prevention of intraoperative periprosthetic fractures during total hip arthroplasty[J].Hip Inter,2011,6:718-723.
- [27]Chen DW,Lin CL,Hu CC,et al.Finite element analysis of different repair methods of Vancouver B1 periprosthetic fractures after total hip arthroplasty[J].Injury,2012,7:1061-1065.
- [28]王少林,谭祖键,周明全.基于偏髓分型应用骨水泥型长短柄假体置换治疗高龄偏髓Ⅰ型粗隆间骨折的有限元分析[J].中国矫形外科杂志,2013,18:1848-1857.
- [29]Lam L,Drew T,Boscainos P.Effect of acetabular orientation on stress distribution of highly cross-linked polyethylene liners[J].Orthopedics,2013,11:1346-1352.
- [30]Elkins JM,Pedersen DR,Callaghan JJ,et al.Do obesity and/or stripe wear increase ceramic liner fracture risk?An XFEM analysis[J].Clin Orthop,2013,2:527-536.
- [31]谭瑞昌,范红松,吴方,等.齿槽型人工髋关节骨应力分布的三维有限元分析[J].生物医学工程学杂志,2011,4:732-736.
- [32]Reimeringer M,Nuno N,Desmarais TC,et al.The influence of uncemented femoral stem length and design on its primary stability:a finite element analysis[J].Computer Methods Biomech Biomed Eng,2013,11:1221-1231.
- [33]Bougherara H,Zdero R,Dubov A,et al.A preliminary biomechanical study of a novel carbon-fibre hip implant versus standard metallic hip implants[J].Med Eng Physics,2011,1:121-128.
- [34]Al-Jassir FF,Fouad H,Alothman OY.In vitro assessment of function graded(FG)artificial hip joint stem in terms of bone/cement stresses:3D Finite Element(FE)study[J].Biomed Eng Online,2013,1:5.
- [35]Kokubo Y,Uchida K,Oki H,et al.Modified metaphyseal-loading anterolaterally flared anatomic femoral stem:five to nine year prospective follow-up evaluation and results of three dimensional finite element analysis[J].Artificial Organs,2013,2:175-182.
- [36]Baharuddin MY,Salleh SH,Suhasril AA,et al.Fabrication of lowcost,cementless femoral stem 316L stainless steel using investment casting technique[J].Artificial Organs,2014,7:603-608.