全髋关节置换术后撞击征
万东东;尤佳;姜文学;
摘要(Abstract):
<正>股髋撞击综合征(femoroacetabular impingement,FAI)最早由瑞士医师Reinhold Ganz提出,它是由于解剖形态学异常,股骨近端和髋臼在关节终末运动期时发生的骨性撞击或
关键词(KeyWords): 全髋关节置换术;撞击征;假体
基金项目(Foundation):
作者(Author): 万东东;尤佳;姜文学;
Email:
DOI:
参考文献(References):
- [1]Brown TD,Callaghan JJ.Impingement in total hip replacement:mechanisms and consequences[J].Curr Orthop,2008,6:376-391.
- [2]Malik A,Maheshwari A,Dorr LD.Impingement with total hip re-placement[J].J Bone Joint Surg Am,2007,9:1832-1842.
- [3]Danesh-Clough T,Bourne RB,Rorabeck CH,et al.The mid-term results of a dual offset uncemented stem for total hip arthro-plasty[J].J Arthroplasty,2007,2:195-203.
- [4]Usrey MM,Noble PC,Rudner LJ,et al.Does neck/liner impinge-ment increase wear of ultrahigh-molecular-weight polyethyleneliners[J].J Arthroplasty,2006,21(6 Suppl 2):65-71.
- [5]Widmer KH.Containment versus impingement:finding a compro-mise for cup placement in total hip arthroplasty[J].Int Orthop,2007,1:29-33.
- [6]Lachiewicz PF,Kauk JR.Anterior iliopsoas impingement and ten-dinitis after total hip arthroplasty[J].J Am Acad Orthop Surg,2009,6:337-344.
- [7]罗志平,戴闽.不同股骨头颈直径比与髋臼角对人工髋关节活动的影响[J].中国矫形外科杂志,2005,10:757-760.
- [8]Yoshimine F.The safe-zones for combined cup and neck antever-sions that fulfill the essential range of motion and their optimumcombination in total hip replacements[J].J Biomech,2006,7:1315-1323.
- [9]Tang WM,Chiu KY,Kwan MF,et al.Sagittal pelvic mal-rota-tion and positioning of the acetabular component in total hip arthro-plasty:three-dimensional computer model analysis[J].J OrthopRes,2007,6:766-771.
- [10]Bozic KJ,Kurtz SM,Lau E,et al.The epidemiology of revision to-talhip arthroplasty in the United States[J].J Bone Joint Surg Am,2009,1:128-133.
- [11]Padgett DE,Lipman J,Robie B,et al.Influence of total hip de-sign on dislocation:a computer model and clinical analysis[J].Clin Orthop,2006,447:48-52.
- [12]Duffy P,Masri BA,Garbuz D,et al.Evaluation of patients withpain following total hip replacement[J].Instr Course Lect,2006,55:223-232.
- [13]Dora C,Houweling M,Koch P,et al.Iliopsoas impingement aftertotal hip replacement:the results of non-operative management,tenotomy or acetabular revision[J].J Bone Joint Surg Br,2007,8:1031-1035.
- [14]Kligman M,Furman BD,Padgett DE,et al.Impingement contrib-utes to backside wear and screw-metallic shell fretting in modularacetabular cups[J].J Arthroplasty,2007,2:258-264.
- [15]Wines AP,McNicol D.Computed tomography measurement of theaccuracy of component version in total hip arthroplasty[J].J Ar-throplasty,2006,5:696-701.
- [16]Komeno M,Hasegawa M,Sudo A,et al.Computed tomographic e-valuation of component position on dislocation after total hip arthro-plasty[J].Orthopedics,2006,12:1104-1108.