摘要(Abstract):
[目的]精确的下肢力线和假体的摆放位置是全膝关节置换成功的关键。计算机导航辅助全膝关节置换的出现使之成为可能,并得到了不断改进和发展,获得了令人满意的治疗效果。导航新技术不断开发使计算机的运行环境和操作界面更加友好,为广大学者普遍接受。随着这一技术的进一步完善,计算机辅助手术必将成为全膝关节置换标准方式。未来的研究重点是,开发更小创伤的示踪器固定系统、电子平衡测量仪和智能化截骨锯等。并通过开发影像依从和非影像依从两种方法联合的影像加强导航系统,架起从现有技术向机器人智能化转变的桥梁,以实现完全通过机器人来完成手术操作的最终目标。
关键词(KeyWords): 关节置换;膝关节;计算机辅助手术;手术技术
基金项目(Foundation):
作者(Author): 李晓辉;
Email:
DOI:
参考文献(References):
- [1]Dutton AQ,Yeo S J,Yang KY,et al.Computer-assisted minimally invasive total knee arthroplasty compared with standard total knee ar-throplasty.A prospective,randomized study[J].J Bone Joint Surg(Am),2008,90:2-9.
- [2]Novak EJ,Silverstein MD,Bozic KJ.The cost-effectiveness of com-puter-assisted navigation in total knee arthroplasty[J].J Bone Joint Surg(Am),2007,89:2389-2397.
- [3]Dennis DA,Komistek RD,Mahfouz MR,et al.Multicenter determi-nation of in vivo kinematics after total knee arthroplasty[J].Clin Or-thop Relat Res,2003:37-57.
- [4]Berger RA,Crossett LS,Jacobs JJ,et al.Malrotation causing patel-lofemoral complications after total knee arthroplasty[J].Clin Orthop Relat Res,1998:144-153.
- [5]Tetcr KE.Bregman D,Colwell CW.Accuracy of intramedullary ver-sus extramedullary tibial alignment cutting systems in total knee ar-throplasty[J].Clin Orthop Relat Res,1995:106-110.
- [6]Griffin FM,Insall JN,Scuderi GR.Accuracy of soft tissue balancing in total knee arthroplasty[J].J Arthroplasty,2000,15:970-973.
- [7]Mihalko WM,Boyle J,Clark LD,et al.The variability of intramed-ullary alignment of the femoral component during total knee arthro-plasty[J].J Arthroplasty,2005,20:25-28.
- [8]Clarke RH,Horsley V.THE CLASSIC:on a method of investigating the deep ganglia and tracts of the central nervous system(cerebel-lum)[J].Clin Orthop Relat Res,2007,463:3-6.
- [9]Lavallee S,Sautot P,Troccaz J,et al.Computer-assisted spine surger-y:a technique for accurate transpedicular screwfixation using CTdata and a3-D optical localizer[J].J Image Guid Surg,1995,1:65-73.
- [10]DiGioia AM3rd,Jaramaz B,Colgan BD.Computer assisted ortho-paedic surgery.Image guided and robotic assistive technologies[J].Clin Orthop Relat Res,1998:8-16.
- [11]Delp SL,Stulberg SD,Davies B,et al.Computer assisted knee re-placement[J].Clin Orthop Relat Res,1998:49-56.
- [12]Krackow KA,Bayers-Thering M,Phillips MJ,et al.A new tech-nique for determining proper mechanical axis alignment during total knee arthroplasty:progress toward computer-assisted TKA[J].Ortho-pedics,1999,22:698-702.
- [13]Bathis H,Perlick L,Tingart M,et al.Radiological results of image-based and non-image-based computer-assisted total knee arthroplasty[J].Int Orthop,2004,28:87-90.
- [14]Stockl B,Nogler M,Rosiek R,et al.Navigation improves accuracy of rotational alignment in total knee arthroplasty[J].Clin Orthop Re-lat Res,2004:180-186.
- [15]Pitto RP,Graydon AJ,Bradley L,et al.Accuracy of a computer-as-sisted navigation system for total knee replacement[J].J Bone Joint Surg(Br),2006,88:601-605.
- [16]Bolognesi M,Hofmann A.Computer navigation versus standard in-strumentation for TKA:a single-surgeon experience[J].Clin Orthop Relat Res,2005,440:162-169.
- [17]Kim S J,MacDonald M,Hemandez J,et al.Computer assisted navi-gation in total knee arthroplasty:improved coronal alignment[J].J Arthroplasty,2005,20:123-131.
- [18]Anderson KC,Buehler KC,Markel DC.Computer assisted naviga-tion in total knee arthroplasty:comparison with conventional methods[J].J Arthroplasty,2005,20:132-138.
- [19]Decking R,Markmann Y,Fuchs J,et al.Leg axis after computer-navigated total knee arthroplasty:a.prospective randomized trial comparing computer-navigated and manual implantation[J].J Ar-throplasty,2005,20:282-288.
- [20]Hungerford DS,Krackow KA.Total joint arthroplasty of the knee[J].Clin Orthop Relat Res,1985:23-33.
- [21]Swank ML.Computer-assisted surgery in total knee arthroplasty:re-cent advances[J].Surg Technol Int,2004,12:209-213.
- [22]Ossendorf C,Fuchs B,Koch P.Femoral stress fracture after comput-er navigated total knee arthroplasty[J].Knee,2006,13:397-399.
- [23]Jung HJ,Jung YB,Song KS,et al.Fractures associated with comput-er-navigated total knee arthroplasty.A report of two cases[J].J Bone Joint Surg(Am),2007,89:2280-2284.
- [24]Kalairajah Y,Simpson D,Cossey AJ,et al.Blood loss after total knee replacement:effects of computer-assisted surgery[J].J Bone Joint Surg(Br),2005,87:1480-1482.
- [25]Kalairajah Y,Cossey AJ,Verrall GM,et al.Are systemic emboli re-duced in computer-assisted knee surgery:a prospective,randomised,clinical trial[J].J Bone Joint Surg(Bt),2006,88:198-202.