Harris-Galante Ⅰ非骨水泥型髋臼假体的中远期疗效分析Analysis of mid-term and long-term results of Harris-GalanteⅠacetabular prosthesis in total hip arthroplasty
杨茂伟;孙俊英;曾金才;刘宏鸣;
摘要(Abstract):
[目的]观察分析H/GI人工全髋关节置换术后髋臼假体中、远期疗效。[方法]对1992~2000年采用H/GI人工全髋关节置换术后髋臼假体置换21例(21髋)患者的临床病历和X线片进行回顾性研究。临床随访根据Harris进行评分,X线随访根据DeLee等髋臼分区进行观察。[结果]截止2010年5月10日,随访到19例(19髋),平均随访时间15年(10~18年)。19例中3髋臼杯进行了翻修,集中在术后9~12年。X线片示髋臼假体明确松动3髋、可能松动5髋,内衬磨损率为每年(0.27±0.10)mm。翻修手术中取出的假体表面的骨生长不满意。[结论]H/GI髋臼假体的中、远期疗效不满意。导致较高假体失效率原因包括内衬与金属臼杯设计不合理和过多的螺钉、螺钉孔有关的骨溶解与假体松动。
关键词(KeyWords): H/GI臼杯;聚乙烯磨损;螺钉;螺孔;骨溶解;全髋置换术
基金项目(Foundation):
作者(Author): 杨茂伟;孙俊英;曾金才;刘宏鸣;
Email:
DOI:
参考文献(References):
- [1]Hariss WH.Traumatic arthritis of the hip after dislocation and ace-tabular fractures:treatment by mold arthroplassty.An end-result study using a new method of result evalution[J].J Bone Joint Surg Am,1969,51:737-755.
- [2]戴士峰,周建伟,黄煌渊.髋臼假体前倾角影像评估[J].中国矫形外科杂志,2002,9:293-294.
- [3]Kawamura H,Dunbar MJ,Murray P,et al.The porous coated anatomic total hip replacement:a ten to fourteen-year follow-up study of a ce-mentless total hip arthroplasty[J].J Bone Joint Surg Am,2001,83:1333-1338.
- [4]Parvizi J,Sullivan T,Duffy G,et al.Fifteen-year clinical survivorship of harris-galante total hip arthroplasty[J].J Arthroplasty,2004,19:6.
- [5]Diekerhof CH,Van Der Hart CP,Fidler MF.Dislocation of polyethy-lene liner in ncemented Harris Galante II acetabulum:report of6ca-ses[J].J Arthroplasty,2004,19:661.
- [6]Gonzalez Della Valle A,Rana A,Furman B,et al.Backside wear is low in retrieved modern,modular,and nonmodular acetabular liners[J].Clin Orthop,2005,440:184.
- [7]Nieuwenhuis JJ,Malefijt Jde W,Hendriks JC,et al.Unsatisfactory re-sults with the cementless Omnifit acetabular component dur to poly-ethylene and severe osteolysis[J].Acta Orthop Belg,2005,71:294-302.
- [8]Walter WL,Clabeaux J,Wright TM,et al.Mechanisms for pumping fluid through cementless acetabular components with holes[J].J Ar-throplasty,2005,20:1042.
- [9]Engh CA,Hopper Jr RH,Engh Jr CA.Long-term porouscoated cup survivorship using spikes,screws,and pressfitting for initial fixation[J].J Arthroplasty,2004,19:54.
- [10]Udomkiat R Dorr LD,Wan Z.Cementless hemispheric porous-coated sockets implanted with press-fit technique without screws:average ten-years follow-up[J].J Bone Joint Surg Am,2002,84:1195-1200.