羟基磷灰石涂层髋臼假体的Meta分析Hydroxyapatite coated acetabular cups in primary total hip arthroplasty:a meta-analysis
郭佳勇;尹宗生;刘敬军;王斯晟;李笛;
摘要(Abstract):
[目的]系统评价生物型髋臼假体是否喷涂羟基磷灰石(hydroxyapatite,HA)在临床效果上的差异。[方法]计算机及手工检索相关的中英文文献,收集关于初次全髋关节置换术(total hip arthroplasty,THA)使用HA涂层髋臼假体和无HA涂层髋臼假体的随机对照研究(randomized controlled trial,RCT)并评价纳入研究的方法学质量。利用STATA 12.0软件进行统计分析。[结果]共纳入符合标准的相关文献7篇,纳入618个髋臼假体,Meta分析结果显示,与对照组相比,HA涂层髋臼假体在影像学松动和因松动及各种原因产生的翻修率方面无统计学差异。[结论]HA涂层没有明显改善髋臼假体的稳定性及翻修率。
关键词(KeyWords): 髋假体;关节成形术;置换;髋;羟基磷灰石;Meta分析
基金项目(Foundation):
作者(Author): 郭佳勇;尹宗生;刘敬军;王斯晟;李笛;
Email:
DOI:
参考文献(References):
- [1]齐新生,李雪松,陈辉,等.金属与羟基磷灰石微孔表面股骨植入体与骨结合强度的比较研究[J].中国矫形外科杂志,2001,7:678-679.
- [2]Bidar R,Kouyoumdjian P,Munini E,et al.Long-term results of theabg-1 hydroxyapatite coated total hip arthroplasty:analysis of 111cases with a minimum follow-up of 10 years[J].Orthop TraumatolSurg Res,2009,8:579-587.
- [3]Chung YY,Ki SC,So KY,et al.High revision rate of hydroxyapatite-coated abg-i prosthesis[J].J Orthop Sci,2009,5:543-547.
- [4]Gottliebsen M,Rahbek O,Ottosen PF,et al.Superior 11-year sur-vival but higher polyethylene wear of hydroxyapatite-coated mallory-head cups[J].J Clin Exp Res Hip Pathol Ther,2012,1:35-40.
- [5]Datir SP,Angus PD.Long term survival of an hydroxyapatite-coatedthreaded cup in the presence of a high polythene wear rate[J].JClin Exp Res Hip Pathol Ther,2010,3:327-334.
- [6]Kim SY,Kim DH,Kim YG,et al.Early failure of hemispherichydroxyapatite-coated acetabular cups[J].Clin Orthop,2006,446:233-238.
- [7]Laursen MB,Nielsen PT,Soballe K.Bone remodelling around ha-coated acetabular cups:a dexa study with a 3-year follow-up in arandomised trial[J].Int Orthop,2007,2:199-204.
- [8]Capello WN,D'Antonio JA,Manley MT,et al.Arc-depositedhydroxyapatite-coated cups:Results at four to seven years[J].Clin Orthop,2005,441:305-312.
- [9]Stilling M,Rahbek O,Soballe K.Inferior survival of hydroxyapatiteversus titanium-coated cups at 15 years[J].Clin Orthop,2009,11:2872-2879.
- [10]Field RE,Rushton N.Five-year clinical,radiological and postmortemresults of the cambridge cup in patients with displaced fractures of theneck of the femur[J].J Bone Joint Surg Br,2005,10:1344-1351.
- [11]Roffman M,Kligman M.Cementless coated and noncoated mathys ac-etabular cups:radiographic and histologic evaluation[J].Orthope-dics,1999,1:39-41.
- [12]Krismer M,Fischer M,Mayrhofer P,et al.A prospective study of themigration of two acetabular components.Pca versus rm cups[J].IntOrthop,1994:23-28.
- [13]Ullmark G,Sorensen J,Nilsson O.Analysis of bone formation on por-ous and calcium phosphate-coated acetabular cups:a randomisedclinical fluoride pet study[J].J Clin Exp Res Hip Pathol Ther,2012,2:172-178.
- [14]Brooks RA,Field RE,Jones E,et al.A histological study of retrievedcambridge acetabular components[J].J Clin Exp Res Hip Pathol T-her,2010,1:56-63.
- [15]Paulsen A,Pedersen AB,Johnsen SP,et al.Effect of hydroxyapatitecoating on risk of revision after primary total hip arthroplasty in youn-ger patients:findings from the danish hip arthroplasty registry[J].Acta Orthop,2007,5:622-628.
- [16]Sharp RJ,O'Leary ST,Falworth M,et al.Analysis of the results of thec-fit uncemented total hip arthroplasty in young patients withhydroxyapatite or porous coating of components[J].J Arthroplasty,2000,5:627-634.
- [17]Lazarinis S,Karrholm J,Hailer NP.Effects of hydroxyapatite coatingof cups used in hip revision arthroplasty[J].Acta Orthop,2012,5:427-435.
- [18]Lazarinis S,Karrholm J,Hailer NP.Increased risk of revision of ace-tabular cups coated with hydroxyapatite[J].Acta Orthop,2010,1:53-59.
- [19]Goosen JH,Kums AJ,Kollen BJ,et al.Porous-coated femoral com-ponents with or without hydroxyapatite in primary uncemented totalhip arthroplasty:a systematic review of randomized controlled trials[J].Arch Orthop Trauma Surg,2009,9:1165-1169.
- [20]Gandhi R,Davey JR,Mahomed NN.Hydroxyapatite coated femoralstems in primary total hip arthroplasty:a meta-analysis[J].J Arthro-plasty,2009,1:38-42.