PEEK椎弓根螺钉内固定系统对椎间盘内压力变化影响的生物力学研究Biomechanical study on the effect of PEEK rods system on the intradiscal pressure of adjacent segments
许小多;于秀淳;黄伟敏;孔令南;
摘要(Abstract):
[目的]通过体外生物力学实验分析PEEK棒椎弓根螺钉内固定系统对相邻节段椎间盘内压力(Intradiscal pressure,IDP)的影响。[方法]取10具适当长度新鲜的羊脊柱标本(L_3~L_6),对每具标本依次行不同方式内固定处理,依据处理方式分为以下5个实验组:未处理组(Intact组)、钛棒单节段融合组(TS组)、PEEK棒单节段融合组(PS组)、PEEK棒双节段杂交组(PD组)和钛棒双节段融合组(TD组)。每个标本通过MTS多自由度脊柱运动模拟测试系统完成前屈、后伸、左/右侧弯、左/右扭转6个方向的完整动作。轴向压力为50 N,扭矩大小为:3 N.m。运用针孔式压力传感器测试每个方向运动状态下的椎间盘压力值。[结果]TS组及PS组的上位邻近节段IDP值高于Intact组(P<0.05);PS组上位相邻节段椎间盘压力值明显低于TS组(P<005);PD组过渡阶段椎间盘压力值明显低于TS组上位相邻节段椎间盘压力值(P<0.05);PD组上位相邻节段椎间盘压力值明显低于TD组(P<0.05)。[结论]与坚强固定相比,应用PEEK棒椎弓根螺钉内固定系统可显著降低相邻节段椎间盘内压力,这可能是降低相邻节段退变发生的理论基础。
关键词(KeyWords): 相邻节段退变;PEEK棒椎弓根螺钉内固定系统;椎间盘内压力;生物力学
基金项目(Foundation):
作者(Author): 许小多;于秀淳;黄伟敏;孔令南;
Email:
DOI:
参考文献(References):
- [1]Szpalski M,Gunzburg R.Lumbar spinal stenosis in the elderly:an overview[J].Eur Spine J,2003,12(Suppl 2):170-175.
- [2]Yu XC,Zhu L.Lumbar spine stability after combined application of interspinous fastener and modifed posterior lumbar interbody fusion:a biomechanical study[J].Arch Orthop Trauma Surg,2014,134(5):623-629
- [3]Salzberg L.The physiology of low back pain[J].Prim Care(2012),39(3):487-498
- [4]Forouzanfar MH,Alexander L,Anderson HR,et al.Global,regional,and national comparative risk assessment of 79 behavioural,environmental and occupational,and metabolic risks or clusters of risks in 188 countries,1990-2013:a systematic analysis for the Global Burden of Disease Study 2013[J].Lancet,2015,386:2287-2323.
- [5]Mummaneni p V,et al.Lumbar interbody fusion:state-of-the-art technical advances.Invited submission from the Joint Section Meeting on Disorders of the Spine and peripheral Nerves,March2004[J].J Neurosurg Spine,1(1):24-30.
- [6]Radcliff KE,Kepler CK,Jakoi A et al.Adjacent segment disease in the lumbar spine following different treatment interventions[J].Spine J,2013,13(10):1339-1349.
- [7]黄伟敏,于秀淳,刘磊,等.Hybrid手术治疗下腰椎退行性疾病的研究进展[J].脊柱外科杂志,2015,13(5):311-314.
- [8]Li C,Liu L,Shi JY,et al.Clinical and biomechanical researches of polyetheretherketone(PEEK)rods for semi-rigid lumbar fusion:a systematic review[J].Neurosurg Rev,2016,41(2):1-15.
- [9]Heo Y,Park JH,Seong HY,et al.Symptomatic adjacent segment degeneration at the L3-4 level after fusion surgery at the L4-5 level:evaluation of the risk factors and 10-year incidence[J].Eur Spine J,2015,24(11):2474-2480.
- [10]Jahng TA,Kim YE,Moon KY.Comparison of the biomechanical effect of pedicle-based dynamic stabilization:a study using finite element analysis[J].Spine J,2013,13(1):85-94.
- [11]Hans-Joachim Wile,et al.Are sheep spines a valid biomechanical modle for human spines[J].Spine,1997,22(20):2323-2330.
- [12]Smit TH.The use of a quadruped as an in vivo model for the study of the spine-biomechanical considerations[J].Eur Spine J,2002,11(2):137-144.
- [13]Kettler A,Liakos L,Haegele B,et al.Are the spines of calf,pig and sheep suitable models for pre-clinical implant tests[J].Eur Spine J,2007,16(12):2186-2192.
- [14]Pradhan BB,Turner AW,Zatushevsky MA,et al.Biomechanical analysis in a human cadaveric model of spinous process fxation with an interlaminar allograft spacer for lumbar spinal stenosis.Laboratory investigation[J].J Neurosurg Spine,2012,16(6):585-593.
- [15]Schultz AB,Warwick DN,Berkson MH,et al.Mechanical propryies of human lumbar spine motion segments-1.responses in flexion,extension,lateral bending,and torsion[J].J Biomech Engin,1979,101(1):46-52.
- [16]Dooris AP,et al.Experimental and theoretical investigations into the effects of artificial disc implantation on the lumbar spine[J/OL].IET Electric Power App,2009,Eo B gw S ID OEUBR,Doi:10.1049/iet-epa.2009.0165
- [17]Gornet MF,Chan FW,Coleman JC,et al.Biomechanical assessment of a PEEK rod system for semi-rigid fixation of lumbar fusion constructs[J].J Biomech Eng,2011,133(8):081009.
- [18]Sengupta DK,Bucklen B,Mc Afee PC,et al.The comprehensive biomechanics and load-sharing of semirigid PEEK and semirigid posterior dynamic stabilization systems[J].Adv Orthop,2013,2013:745610.
- [19]Handa T,Ishihara H,Ohshima H,et al.Effects of hydrostatic pressure on matrix synthesis and matrix metalloproteinase production in the human lumbar intervertebral disc[J].Spine,1997,22(10):1085-1091.
- [20]Hung YJ,Shih TT,Chen BB,et al.The dose-response relationship between cumulative lifting load and lumbar disk degeneration based on magnetic resonance imaging findings[J].Phys Ther,2014,94(11):1582-1593.
- [21]Bridwell KH,Sedgewick TA,O’Brien MF,et al.The role of fusion and instrumentation in the treatment of degenerative spondylolisthesis with spinal stenosis[J].J Spinal,1993,Disord6:461-472.
- [22]Kim TY,Kang KT,Yoon DH,et al.Effects of lumbar arthrodesis on adjacent segments:differences between surgical techniques[J].Spine(Phila Pa 1976),2012,37(17):1456-1462.
- [23]Kim DK,Lim H.Clinical and radiological comparison of semirigid(Wavefle X)and rigid system for the lumbar spine[J].Korean Journal of Spine,2016,13(2):57-62.
- [24]Xia XP,Chen HL,Cheng HB.Prevalence of adjacent segment degeneration after spine surgery:a systematic review and meta-analysis[J].Spine,2013,38(7):597-608.
- [25]Radcliff KE,Kepler CK,Jakoi A,et al.Adjacent segment disease in the lumbar spine following different treatment interventions[J].Spine J,2013,13(10):1339-1349.
- [26]Turner JA,Ersek M,Herron L,et al.Patient outcomes after lumbar spinal fusions[J].JAMA,1992,268(7):907-911.
- [27]Lee CS,Hwang CJ,Lee S-W,et al.Risk factors for adjacent segment disease after lumbar fusion[J].Eur Spine J,2009,18(11):1637-1643.
- [28]Athanasakopoulos M,Mavrogenis AF,Triantafyllopoulos G,et al.Posterior spinal fusion using pedicle screws[J].Orthopedics,2013,36(7):951-957.
- [29]Chou WK,Chien A,Wang JL.Biomechanical analysis between PEEK and titanium screw-rods spinal construct subjected to fatigue loading[J].J Spinal Disord Tech,2015,28(3):121-125.
- [30]Schwarzenbach O,Rohrbach N,Berlemann U.Segment-by-segment stabilization for degenerative disc disease:a hybrid technique[J].Eur Spine J,2010,19(6):1010-1020.
- [31]Asher MA,Carson WL,Hardacker JW,et al.The effect of arthrodesis,implant stiffness,and time on the canine lumbar spine[J].J Spinal Disord Tech,2007,20(8):549-559.
- [32]Schwab FJ,Nazarian DG,Mahmud F,et al.Effects of spinal instrumentation on fusion of the lumbosacral spine[J].Spine,1995,20(18):2023-2028.
- [33]Kowalski RJ,Ferrara LA,Benzel EC.Biomechanics of bone fusion[J].Neurosurg Focus,2001,10(4):E2.
- [34]Siebert E,Pruss H,Klingebiel R,et al.Lumbar spinal stenosis:syndrome,diagnostics and treatment[J].Nat Rev Neurol,2009,5(7):392-403.
- [35]Hudson WR,Gee JE,Billys JB,et al.Hybrid dynamic stabilization with posterior spinal fusion in the lumbar spine[J].SAS J,2011,5(12):36-43.