髋关节置换股骨侧骨水泥鞘质量和厚度分析Evaluation of quality and thickness of cement mantle on femoral side in hip arthroplasty
蔡宏;张克;田华;刘岩;李子剑;
摘要(Abstract):
[目的]分析髋关节置换骨水泥型股骨假体周围水泥鞘的质量和厚度。[方法]回顾北京大学第三医院骨科自2004年2月-2007年12月采用相同入路、操作技术和假体完成的262例(279髋)初次髋关节置换病例,分析术后出院前X线片,对股骨侧骨水泥鞘质量和厚度进行分析。[结果](1)按Barrack标准,骨水泥质量A级87.1%,B级11.8%,C级1.1%,无D级骨水泥;(2)按Gruen分区,骨水泥鞘厚度<2mm区域多见于正位片上1、2、5区和侧位片上8、9、12区;透亮带多位于假体中远端的2~5区和10~12区;气泡影出现在假体远端的3~5区和10~12区。(3)股骨假体和股骨解剖轴线在正位片上的夹角,在骨水泥鞘厚度>2mm组中为1.46°±0.75°(-1.60°~3.41°);在骨水泥鞘厚度<2mm区域组中为3.90°±1.52°(-2.99°~7.69°),两组间差异有统计学意义(P<0.05)。[结论]正确使用第3代骨水泥技术,可获得可靠的骨水泥固定质量。股骨假体应参考股骨解剖轴线中立位置入,以期获得均匀一致,足够厚度的骨水泥鞘。
关键词(KeyWords): 关节成形术,置换,髋;骨水泥;治疗结果
基金项目(Foundation):
作者(Author): 蔡宏;张克;田华;刘岩;李子剑;
Email:
DOI:
参考文献(References):
- [1]Callaghan JJ,Templeton JE,Liu SS,et al.Results of Charnley total hip arthroplasty at a minimum of thirty years.Aconcise follow-up of a previous report[J].J Bone Joint Surg(Am),2004,86:690-695.
- [2]Berry DJ,Harmsen WS,Cabanela ME,et al.Twenty-five-year survi-vorship of two thousand consecutive primary Charnley total hip re-placements:factors affecting survivorship of acetabular and femoral components[J].J Bone Joint Surg(Am),2002,84:171-177.
- [3]Ranawat CS,Ranawat AS,Rasquinha VJ.Mastering the art of cemen-ted femoral stem fixation[J].J Arthroplasty,2004,1:85-91.
- [4]周乙雄,刘淼,殷建华,等.第3代骨水泥技术在人工全髋关节置换术中的应用[J].中华医学杂志,2003,83:762-765.
- [5]Barrack RL,Mulroy RD,Harris WH.Improved cementing techniques and femoral component loosening in young patients with hip arthro-plasty.A12-year radiographic review[J].J Bone Joint Surg(Br)1992,74:385-389.
- [6]Gruen TA,McNeice GM,Amstutz HC."Modes of failure"of cemen-ted stem-type femoral components:a radiographic analysis of loose-ning[J].Clin Orthop Relat Res,1979,141:17-27.
- [7]Jasty M,Maloney WJ,Bragdon CR,et al.The initiation of failure in cemented femoral components of hip arthroplasties[J].J Bone Joint Surg(Br),1991,73:551-558.
- [8]Chiu KH,Shen WY,Tsui HF,et al.Experience with primary exeter total hip arthroplasty in patients with small femurs.Reviewat average follow-up period of6years[J].J Arthroplasty,1997,12:267-272.
- [9]周乙雄.第3代骨水泥技术在人工全髋置换术中的应用及随访[J].中国矫形外科杂志,2005,21:1605-1607.
- [10]Breusch SJ,Lukoschek M,Kreutzer J,et al.Dependency of cement mantle thickness on femoral stem design and centralizer[J].J Arthro-plasty,2001,16:648-657.
- [11]Charnley J.Low friction arthroplasty of the hip:theory and practice[M].Berlin:Springer,Heidelberg,1979.
- [12]Ebramzadeh E,Sarmiento A,McKellop HA,et al.The cement mantle in total hip arthroplasty.Analysis of long-term radiographic results[J].J Bone Joint Surg(Am),1994,76:77-87.
- [13]Valdivia GG,Dunbar MJ,Parker DA,et al.The John Charnley A-ward:three-dimensional analysis of the cement mantle in total hip ar-throplasty[J].Clin Orthop Relat Res,2001,393:38-51.