基于影像数据的人工关节无菌性松动的诊断方法
廖广姗;黄敏;蒋海涛;杨顺刚;王金武;戴尅戎;
摘要(Abstract):
<正>人工关节置换术使许多病变关节恢复了功能,提高了病人的生活质量。然而,许多假体在没有达到最大的使用年限之前就不得不进行翻修。人工关节假体无菌性松动是假体置换术后翻修的最主要原因之一,同时也是困扰临床的一大难题。据2010年挪威公布的各类失效所占比例逐年变化的统计,居于首位的无菌性松动目前稳定在50%~60%的水
关键词(KeyWords): 人工关节无菌性松动;影像;诊断;综述
基金项目(Foundation): 国家重大科学研究计划(项目编号:2012CB933604);; 国家自然科学基金(项目编号:81171707);; 上海市浦江人才计划(D类)(编号:11PJD016)基金
作者(Author): 廖广姗;黄敏;蒋海涛;杨顺刚;王金武;戴尅戎;
Email:
DOI:
参考文献(References):
- [1]Haukeland University Hospital.The Norwegian arthroplasty register,the Norwegian cruciate ligament register,the Norwegian hip fractureregister,centre of excellence of joint replacements.Report June 2010[EB/OL],2010.http://nrlweb.ihelse.net/eng/Report_2010.pdf
- [2]Lavernia CJ,Alcerro JC.Quality of life and cost-effectiveness 1year after total hip arthroplasty[J].J Arthroplasty,2011,5:705-709.
- [3]杨庆铭.全髋关节置换术后的假体松动[J].中华关节外科杂志,2009,5:635-638.
- [4]吕丹,孙明林.人工髋关节置换后假体无菌性松动的因素及其防治[J].中国组织工程研究与临床康复,2009,13:2553-2556.
- [5]Yamaguchi M,Bauer TW,Hashimoto Y.Three-dimensional anal-ysis of multiple wear vectors in retrieved acetabular cups[J].J BoneJoint Surg Am,199,10:1539-1544.
- [6]Engh CA Jr,Sychterz CJ,Young AM,et al.Interobserver and in-traobserver variability in radiographic assessment of osteolysis[J].JArthroplasty,2002,6:752-759.
- [7]康焱,邬培慧,张紫机,等.初次全髋关节置换术后5年以上随访结果与分析[J].中华关节外科杂志(电子版),2011,5:546-554.
- [8]Garcia-Cimbrelo E,Tapia M,Martin-Hervas C.Multislice com-puted tomography for evaluating acetabular defects in revision THA[J].Clin Orthop,2007,463:138-143.
- [9]Weiland DE,Walde TA,Leung SB,et al.Magnetic resonance ima-ging in the evaluation of periprosthetic acetabular osteolysis:a cada-veric study[J].J Orthop,2005,4:713-719.
- [10]Toms AP,Marshall TJ,Cahir J,et al.MRI of early symptomaticmetal-on-metal total hip arthroplasty:a retrospective review ofradiological findings in 20 hips[J].Clin Radiol,2008,1:49-58.
- [11]庞清江.全髋关节置换术后假体无菌性松动的影像学诊断[J].现代实用医学,2011,11:1201-1203.
- [12]Viceconti M,Brusi G,Pancanti A,et al.Primary stability of an ana-tomical cementless hip stem:a statistical analysis[J].J Biomech,2006,39:1169-1179.
- [13]Lennon AB,Britton JR,MacNiocaill RF,et al.Predicting revisionrisk for aseptic loosening of femoral components in total hip arthro-plasty in individual patients-a finite element study[J].J OrthopRes,2007,6:779-788.
- [14]McCalden RW,Naudie DD,Yuan X,et al.Radiographic methods forthe assessment of polyethylene wear after total hip arthroplasty[J].J Bone Joint Surg Am,2005,10:2323-2334.
- [15]de Bruin PW,Kaptein BL,Stoel BC,et al.Image-based RSA:Roentgen tereophotogrammetric analysis based on 2D-3D imageregistration[J].J Biomech,2008,41:155-164.
- [16]Li G,Van de Velde SK,Bingham JT.Validation of a non-invasivefluoroscopic imaging technique for the measurement of dynamic kneejoint motion[J].J Biomech,2008,41:1616-1622.
- [17]Zihlmann MS,Gerber H,Stacoff A,wt al.Three-dimensional kine-matics and kinetics of total knee arthroplasty during level walking u-sing single plane video fluoroscopy and force plates:a pilot study[J].Gait Posture,2006,24:475-481.