磷酸钙复合BMP-2增强骨质疏松椎体椎弓根螺钉内固定Calcium phosphate composited with bone morphogenetic protein-2 for enhancement of pedicle screws in osteoporotic rabbits
钱光;余月明;董有海;洪洋;王明海;
摘要(Abstract):
[目的]探讨磷酸钙复合BMP-2对骨质疏松状态下椎弓根螺钉稳定性的影响,评价其临床应用价值。[方法]雌性新西兰大白兔卵巢切除去势法制备骨质疏松模型,测量骨密度。将兔随机分为增强组和常规组,增强组采用磷酸钙复合BMP-2注入增强后置入椎弓钉,而常规组采用常规技术置入椎弓钉。置钉后4、8和12周分别进行骨组织形态计量检查和生物力学检测。[结果]与术前比较,卵巢切除后6个月的BMD显著下降(P<0.05),提示骨质疏松模型建立成功。置入L3椎弓螺钉术后4、8和12周,增强组和常规组骨形态计量指标比较,类骨质表面、骨-螺钉接触、骨内生和骨矿物沉积速率,均随时间延长显著增加,相同时间点增强组各项指标优于常规组,差异有统计学意义(P<0.05)。生物力学测试表明,置钉后4、8和12周,随着固定时间延长,两组的最大拔出力和最大破坏功耗均显著增加,相同时间点,增强组的最大拔出力和最大破坏功耗均显著大于常规组,差异有统计学意义(P<0.05)。[结论]磷酸钙复合BMP-2可以增强椎弓根螺钉在骨质疏松椎体中的稳定性,具有一定的临床应用价值。
关键词(KeyWords): 骨质疏松症;椎弓根螺钉;磷酸钙;骨形态发生蛋白
基金项目(Foundation): 上海市卫生和计划生育委员会科研课题面上项目(编号:201540312)
作者(Author): 钱光;余月明;董有海;洪洋;王明海;
Email:
DOI:
参考文献(References):
- [1]Girardo M,Cinnella P,Gargiulo G,et al.Surgical treatment of osteoporotic thoraco-lumbar compressive fractures:the use of pedicle screw with augmentation PMMA[J].Eur Spine J,2017,26(Suppl 4):546-551.
- [2]Erdem MN,Karaca S,Sar?S,et al.Application of cement on strategic vertebrae in the treatment of the osteoporotic spine[J].Spine J,2017,17(3):328-337.
- [3]Chandra VV,Prasad BC,Jagadeesh MA,et al.Segmental polymethylmethacrylate-augmented fenestrated pedicle screw fixation for lumbar spondylolisthesis in patients with osteoporosis-A case series and review of literature[J].Neurol India,2017,65(1):89-95.
- [4]钱光,杨文成,王明海,等.负载骨形态发生蛋白新型骨填充材料应用于椎体成形[J].中国组织工程研究,2012,16(25):4571-4575.
- [5]Zarrinkalam MR,Beard H,Schultz CG,et al.Validation of the sheep as a large animal model for the study of vertebral osteoporosis[J].Eur Spine J,2009,18(2):244-253.
- [6]Augat P,Simon U,Liedert A,et al.Mechanics and mechanobiology Of fracture healing in normal and osteoporotic bone[J].Osteoporos Int,2005,16(Suppl 2):S36-43.
- [7]Simpson AH,Murray IR.Osteoporotic fracture models[J].Curr Osteoporos Rep,2015,13(1):9-15.
- [8]Varghese V,Saravana Kumar G,Krishnan V.Effect of various factors on pull out strength of pedicle screw in normal and osteoporotic cancellous bone models[J].Med Eng Phys,2017,40(1):28-38.
- [9]Liu D,Shi L,Lei W,et al.Biomechanical comparison of expansive pedicle screw and polymethylmethacrylate-augmented pedicle screw in osteoporotic synthetic bone in primary implantation:an experimental study[J].Clin Spine Surg,2016,29(7):351-357.
- [10]Leichtle CI,Lorenz A,Rothstock S,et al.Pull-out strength of cemented solid versus fenestrated pedicle screws in osteoporotic vertebrae[J].Bone Joint Res,2016,5(9):419-426.
- [11]Schulze M,Gehweiler D,Riesenbeck O,et al.Biomechanical characteristics of pedicle screws in osteoporotic vertebrae-comparing a new cadaver corpectomy model and pure pull-out testing[J].J Orthop Res,2017,35(1):167-174.
- [12]Mutsuzaki H,Ito A,Sakane M,et al.Calcium phosphate coating formed in infusion fluid mixture to enhance fixation strength of titanium screws[J].J Mater Sci Mater Med,2007,18(9):1799-1808.
- [13]Hasegawa T,Inufusa A,Imai Y,et al.Hydroxyapatite coating of pedicle screws improves resistance against pull-out force in the osteoporotie canine lumbar spine model:a pilot study[J].Spine J,2005,5(3):239-243.
- [14]Choma TJ,Pfeiffer FM,Swope RW,et al.Pedicle screw design and cement augmentation in osteoporotic vertebrae:effects of fenestrations and cement viscosity on fixation and extraction[J].Spine(Phila Pa 1976),2012,37(26):1628-1632.
- [15]Shea TM,Laun J,Gonzalez-Blohm SA,et al.Designs and techniques that improve the pullout strength of pedicle screws in osteoporotic vertebrae:current status[J].Biomed Res Int,2014,2014:748393.